Product Category: Informatics & Software   >   Empower
Description
Using Agilent 1100 modules with Empower software
Support Number: TECN1851515 | Publication Date: June 17, 2002 | Content Type: Technical Notes (Service)

This article lists additions to the Empower Software Release Notes that apply to Agilent 1100 modules.

Altered sample set custom field does not retain new value after acquisition
Support Number: TECN1851517 | Publication Date: May 25, 2005 | Content Type: Technical Notes (Service)

Altered sample set custom field does not retain a new value after acquisition.

Empower Build 1154 has been structurally validated with Citrix MetaFrame Presentation Server
Support Number: TECN1851523 | Publication Date: January 11, 2006 | Content Type: Technical Notes (Service)

Empower software Build 1154 has been structurally validated on Citrix MetaFrame Presentation Server, Enterprise Edition Version 4.0 (Build 2198) on Windows 2000 Server with Service Pack 4.

ApexTrack Gaussian Skimming Criteria
Support Number: TECN1851601 | Publication Date: December 9, 2003 | Content Type: Technical Notes (Service)

This article discusses ApexTrack Gaussian Skimming criteria.

Using wildcards in Peak type intersample custom field calculations
Support Number: TECN1851545 | Publication Date: September 2, 2003 | Content Type: Technical Notes (Service)

This article shows an example of how to use wildcards in Peak type intersample custom field calculations.

Possible causes for A1100 errors reported in the Millennium32 or Empower Message Center
Support Number: TECN1851558 | Publication Date: April 28, 2005 | Content Type: Technical Notes (Service)

A1100 errors reported in the Millennium/Empower Message Center with details on how they are generated with possible ways to avoid these errors.

Non-sequential Result IDs
Support Number: TECN1851615 | Publication Date: August 10, 2005 | Content Type: Technical Notes (Service)

This article explains how it is possible to have Result IDs that are out of sequence when your order them by Date Processed

Printing Holmium spectrum
Support Number: TECN1851631 | Publication Date: March 14, 2005 | Content Type: Technical Notes (Service)

This article describes how to print Holmium spectrum with an Agilent 1100.

Update on testing of Waters software with Microsoft Hotfixes
Support Number: TECN1851635 | Publication Date: September 22, 2005 | Content Type: Technical Notes (Service)

Waters has completed regression testing of Empower with selected Micosoft Hotfixes. This test is not a complete structural validation.

Custom fields processing codes
Support Number: TECN1851649 | Publication Date: January 4, 2005 | Content Type: Technical Notes (Service)

This article discusses custom fields processing codes that involve the POW function.

Equinox serial board driver compatibility issues with Empower
Support Number: TECN1851571 | Publication Date: May 11, 2005 | Content Type: Technical Notes (Service)

Waters has identified a compatibility issue with the Equinox serial board driver Version 5.10.2.2 and Empower software running on Microsoft Windows XP Service Pack 2.

Validation of new Equinox serial board driver
Support Number: TECN1851573 | Publication Date: May 6, 2005 | Content Type: Technical Notes (Service)

Version 5.30.0.5 of the Equinox serial board driver has been installed and tested, and is now validated for use in LAC/E32 acquisition servers running Empower Release 1154 with Windows XP Service Pack 2.

Empower and Dr. Watson
Support Number: TECN1851575 | Publication Date: May 31, 2005 | Content Type: Technical Notes (Service)

Waters recommends that you disable Dr Watson when running Empower software.

Supported PDA detector data rates with Empower software
Support Number: TECN1851727 | Publication Date: June 17, 2002 | Content Type: Technical Notes (Service)

This article lists the PDA detector data rates that Empower software supports.

Considerations Using Agilent 5890 and Agilent 6890 GCs with Empower software
Support Number: TECN1851729 | Publication Date: June 13, 2002 | Content Type: Technical Notes (Service)

This article lists additions to the Empower Software Release Notes that apply to Agilent 5890 and Agilent 6890 gas chromatographs (GCs).

Using 2695 and 2795 separations modules with Empower software
Support Number: TECN1851731 | Publication Date: June 13, 2002 | Content Type: Technical Notes (Service)

This article lists additions to the Empower Software Release Notes that apply to 2695 and 2795 separations modules.

Application error while using the Empower QuickStart interface
Support Number: TECN1851733 | Publication Date: March 19, 2003 | Content Type: Technical Notes (Service)

This note explains a possible cause for an application error while using the Empower QuickStart interface in Run Samples.

Empower validated on Windows 2000 SP4 with security Hotfix (Microsoft Security Bulletin MS03-026)
Support Number: TECN1851667 | Publication Date: January 5, 2004 | Content Type: Technical Notes (Service)

Empower software has been structurally validated on Microsoft Windows 2000 SP4 with the security update (Hotfix) addressed by Microsoft Security Bulletin MS03-026.

Creating and copying preferences
Support Number: TECN1851713 | Publication Date: April 18, 2005 | Content Type: Technical Notes (Service)

This article overview the copy preferences function.

Empower Message Center error messages
Support Number: TECN1851750 | Publication Date: July 14, 2004 | Content Type: Technical Notes (Service)

In a network environment, some of the Empower Message Center properties are decentralized in nature, and are reset each time that you add new clients or LAC/E32 acquisition servers to the network.

Empower control of Agilent 7694 Headspace Analyzer - Instrument Failure
Support Number: TECN1851837 | Publication Date: November 10, 2004 | Content Type: Technical Notes (Service)

An Instrument Failure may occur exactly 10 minutes after the GC run has ended in a Empower-controlled GC system containing an Agilent 7694 Headspace Analyzer.

Defects fixed and suggestions implemented in Empower Software Build 1154
Support Number: TECN1851770 | Publication Date: July 22, 2002 | Content Type: Technical Notes (Service)

This article lists the defects and suggestions reported in Millennium32 software that were fixed or implemented in Empower Software Build 1154.

Column temperature exceeds the setpoint on a 1525 pump
Support Number: TECN1851826 | Publication Date: September 20, 2002 | Content Type: Technical Notes (Service)

If your system contains a Waters 1525 pump and a TCM and the column temperature exceeds the specified high temperature setpoint, you may not receive an instrument failure.

Valley-to-Valley and Gaussian Skim Events are not available with ApexTrack integration
Support Number: TECN1851830 | Publication Date: June 12, 2002 | Content Type: Technical Notes (Service)

The Valley-to-Valley and Gaussian Skim timed events are not currently available when using a processing method with ApexTrack integration.

Empower and Millennium32 Version 4.0 software have been validated with the Hotfix addressed by Micro...
Support Number: TECN1851854 | Publication Date: April 27, 2006 | Content Type: Technical Notes (Service)

Empower has been structurally validated on Windows XP SP1a, and Millennium32 Version 4.0 for Windows NT 4.0 SP6a and Windows 2000 SP4 with the security hotfix addressed by Microsoft Security Bulletin MS03-026, and Citrix MetaFrame XPe.